Skip to content

TechDirectArchive

Hands-on IT, Cloud, Security & DevOps Insights

  • Home
  • About
  • Advertise With US
  • Contact
  • Reviews
  • Toggle search form
Home » Virtualization » How to install ESXi on a Beelink EQ12 Mini PC
  • Remote Desktop 2 1
    How to install RDS via Quick Start Deployment: Install, Publish, Update, and Uninstall Remote Desktop Web Client Web Server
  • Screenshot 2022 03 21 at 18.06.30
    How to Configure Virtual Host for Apache HTTP Web Server to Host Several Domains on Ubuntu 20.04 LTS Linux
  • wacxx
    Install Windows Admin Center in an unattended mode using a self-signed certificate Windows
  • unnamed 2
    How to create a contact in Active Directory Windows Server
  • Windows Deployment Services
    How to migrate WDS and MDT to a new Windows Server Windows Server
  • sadx
    Error 0x80070002: When trying to mount an image file Windows Server
  • Deploy BitLocker on Windows Server manually
    Install BitLocker on Windows Server via the Server Manager Windows Server
  • Implement Split Brain DNS Policies in Active Directory
    Implement Split-Brain DNS Policies in Active Directory Windows Server

How to install ESXi on a Beelink EQ12 Mini PC

Posted on 06/02/202406/02/2024 Christian By Christian No Comments on How to install ESXi on a Beelink EQ12 Mini PC
VMware Type 1 Hypervisor installation

In this article, I will be showing you the steps on “How to install ESXi on a Beelink EQ12 Mini PC”. I have been looking for cost-effective home appliances to retire my old IT gear. Then I decided between the Intel NUC 13 which is very expensive and “Beelink EQ12 Mini PC. Please see IP Address blocked on Synology NAS due to forgotten Password, how to Install Azure DevOps Server 2022, and Upgrade Microsoft Office 2019 to 2021 on Mac.

Since I will be installing VMware ESXi Version 8 Update 2, it makes sense to discuss and refer you to the new capabilities available. This release includes not only the enterprise workload platform but also includes a new cloud service that will be available to users of vSphere+.

These updates will help enhance the operational efficiencies of IT admins, supercharge the performance of demanding workloads, and accelerate the pace of innovation for DevOps engineers, developers, and anyone else who can benefit from self-service access to infrastructure services.

Beelink EQ12

Beelink EQ12 mini PC has an Intel 12th Alder Lake-N100 processor with 4 Cores, 4 Threads and 6MB L3 cache. The processor’s Thermal Design Power (TDP) can reach 25W, and the Max Turbo Frequency is 3.4GHz.

The performance of the N100 is comparable to the 10th generation Core i3 series processors with TDP configured at 25W, and is more than 30% better than the previous generation Intel Jasper Lake Celeron N5105. Apart from excellent performance, EQ12 features two 2.5G Ethernet ports.

Furthermore, it has a 16G DDR5, 500G PCIe SSD Mini Computer W11 Pro, TDP/WiFi 6/BT5.2/Triple Display”. From my test as of now, I find the Beelink EQ12 very useful for my Lab needs. Below are the images of the Beelink Mini PCs.

Write the VMware ESXi v8 Update 2 ISO file to a USB with Rufus

Go to the Rufus download. page Click the latest release (first link) in the “Download” section and save the file

Here are some articles discussing how to burn an ISO image to a USB drive. How to create a Windows 11 Bootable USB drive, how to Mount an ISO image in Windows 10 and 11, how to create a dual-boot setup on Windows 11, and Create a Windows 10 or 11 bootable USB with UEFI support. Also, see Create a Bootable USB Drive Using dd Command on Linux, and USB Drive: Create a Multiboot with Multiple OS ISOs.

Run the Rufus.exe file to launch the tool. Under the “Device” section, select the ISO Image. I am fine with the default settings.

VMware-ESXi-on-Rufus

Select OK to confirm the warning to destroy all data on the drive.

Wipe-Data

Click Start and on the prompt, select “Write in ISO Image Mode (recommended). Click OK. When Ready, click on Close.

ISO-Image-mode

Install VMware ESXi

After the writing is finished, plug the USB Drive into the EQ12 host. Press the F7 key after booting and select the USB drive press the [Enter] button to enter the ESXi installer.

Boot-Device

The loading process may be slow, please be patient.

Loading-Installer
ESXi-loaded-successfully

After entering the installation page, press the Enter key to the next step.

Choose-Action-to-Perform

Hit the F11 key to continue the installation

Accept-and-Continue

Scanning is performed

Scanning-for-available-devices

Additional Information is being gathered from the selected device. Exercise patience once more.

Scanning

Select the local storage to overwrite. Press the Enter key

Confirm-Disk-Selection

I am fine with the default keyboard layout. You can use the arrow key to select your favourite.

Keyboard-layout

Here is how to Setup Windows server backup and create backup jobs with Bare metal backup, and how to install PSD Hydration Kit for remote bare-metal deployment or via PXE boot.

Set Root Password

Enter the root password in the field below and press the Enter key

Enter-Password-1

Install

 Use the F11 key and wait for the installation process to complete

Installation-Progress-1

When the installation completes, unplug the USB drive, press the Enter key and wait for the PC to reboot.

Enter-to-Reboot

Server is being rebooted.

Rebooting-Server

After rebooting, the following page indicates that you have finished the installation of ESXi system

Manage-ESXi-Host

See How to install ESXi on VirtualBox, learn the Differences between vSphere and ESXi and Center, and how to remove Recent vSphere Client Connections.

Configure Networking: Set Static IP Address

Note: If you skip step the below steps, the default parameters will automatically apply

Press the F2 key to set a static IP address. You need to enter the password. The login name: root, and the password you have set during the system installation.

Enter-Password-2

Use the down arrow keys to select [configure management network] and press the Enter key.

Configure-Network-management
Network-Management

Locate the IPV4 configuration and press the Enter key.

IPv4-set-up-ESXi

Select the third item and press the spacebar to confirm the selection. Fill in the static IP address of the ESXi as you wish.

Set-static-Ipv4

As you can see below, we have manually set the IP address. This means, it is static and will not change after a reboot etc.

Manual-IPv4

Please select “yes” to save

Yes-to-apply-changes

You have successfully completed the ESXi installation and configuration. Enter the IP address that was automatically assigned to access the client. Enter the password to log in to the backend management.

Login-to-ESXi

Congratulations, that is all it takes to install VMware ESXi. Next, we shall install the Center Server.

vSphere-Environment

I hope you found this article useful on “how to install ESXi on a Beelink EQ12 Mini PC”. Please feel free to leave a comment below.

5/5 - (1 vote)

Thank you for reading this post. Kindly share it with others.

  • Click to share on X (Opens in new window) X
  • Click to share on Reddit (Opens in new window) Reddit
  • Click to share on LinkedIn (Opens in new window) LinkedIn
  • Click to share on Facebook (Opens in new window) Facebook
  • Click to share on Pinterest (Opens in new window) Pinterest
  • Click to share on Tumblr (Opens in new window) Tumblr
  • Click to share on Telegram (Opens in new window) Telegram
  • Click to share on WhatsApp (Opens in new window) WhatsApp
  • Click to share on Pocket (Opens in new window) Pocket
  • Click to share on Mastodon (Opens in new window) Mastodon
  • Click to share on Bluesky (Opens in new window) Bluesky
  • Click to share on Threads (Opens in new window) Threads
  • Click to share on Nextdoor (Opens in new window) Nextdoor
Virtualization Tags:ESXi, Hypervisor, virtualization

Post navigation

Previous Post: IP Address blocked on Synology NAS due to forgotten Password
Next Post: Install Proxmox VE on a Beelink EQ12 Mini PC

Related Posts

  • maxresdefault
    How to extend a VM Hard Disk on VMware Workstation Virtualization
  • Slide2 2
    Oracle VirtualBox: Installing Windows 11 without TPM Support Virtualization
  • ESNAS Virtualization 01
    How to remove Recent vSphere Client Connections Virtualization
  • Cloud Cost
    How to Control Cloud Cost Using Azure VM AWS/Azure/OpenShift
  • veeam backup for Proxmox VE
    Backup and Restore Proxmox VE virtual machines with Veeam Backup
  • MAP virtual disk error
    Install Workstation Pro 17: Fix failed to initialise library for mounting and unmounting virtual disks Virtualization

More Related Articles

maxresdefault How to extend a VM Hard Disk on VMware Workstation Virtualization
Slide2 2 Oracle VirtualBox: Installing Windows 11 without TPM Support Virtualization
ESNAS Virtualization 01 How to remove Recent vSphere Client Connections Virtualization
Cloud Cost How to Control Cloud Cost Using Azure VM AWS/Azure/OpenShift
veeam backup for Proxmox VE Backup and Restore Proxmox VE virtual machines with Veeam Backup
MAP virtual disk error Install Workstation Pro 17: Fix failed to initialise library for mounting and unmounting virtual disks Virtualization

Leave a Reply Cancel reply

You must be logged in to post a comment.

Microsoft MVP

VEEAMLEGEND

vexpert-badge-stars-5

Virtual Background

GoogleNews

Categories

veeaam100

sysadmin top30a

  • Remote Desktop 2 1
    How to install RDS via Quick Start Deployment: Install, Publish, Update, and Uninstall Remote Desktop Web Client Web Server
  • Screenshot 2022 03 21 at 18.06.30
    How to Configure Virtual Host for Apache HTTP Web Server to Host Several Domains on Ubuntu 20.04 LTS Linux
  • wacxx
    Install Windows Admin Center in an unattended mode using a self-signed certificate Windows
  • unnamed 2
    How to create a contact in Active Directory Windows Server
  • Windows Deployment Services
    How to migrate WDS and MDT to a new Windows Server Windows Server
  • sadx
    Error 0x80070002: When trying to mount an image file Windows Server
  • Deploy BitLocker on Windows Server manually
    Install BitLocker on Windows Server via the Server Manager Windows Server
  • Implement Split Brain DNS Policies in Active Directory
    Implement Split-Brain DNS Policies in Active Directory Windows Server

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 1,839 other subscribers
  • RSS - Posts
  • RSS - Comments
  • About
  • Authors
  • Write for us
  • Advertise with us
  • General Terms and Conditions
  • Privacy policy
  • Feedly
  • Telegram
  • Youtube
  • Facebook
  • Instagram
  • LinkedIn
  • Tumblr
  • Pinterest
  • Twitter
  • mastodon

Tags

Active Directory AWS Azure Bitlocker Microsoft Windows PowerShell WDS Windows 10 Windows 11 Windows Server 2016

Copyright © 2025 TechDirectArchive

 

Loading Comments...
 

You must be logged in to post a comment.